REV 2 - 1502191555L-C2-3871Important: READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OR USE.WALL VENT HOODFor Outdoor Use Only36-VH,
REV 2 - 1502191555L-C2-38710ROOFSOFFIT *(To enclose transition and area above hood. Some installs may not require a soffi t, as countertop height &
REV 2 - 1502191555L-C2-38711THIS VENT HOOD IS FOR OUTDOOR, WALL MOUNT INSTALLATION ONLY.To ensure safety and proper performance; the vent hood install
REV 2 - 1502191555L-C2-38712INSTALLATION (cont.)Custom Spacer:Construct the spacer frame according to your individual install preference, while follow
REV 2 - 1502191555L-C2-38713INSTALLATION (cont.)WALL MOUNT BRACKETThe wall mount bracket must be installed into the spacer to assist in supporting the
REV 2 - 1502191555L-C2-38714VENT HOOD1. Rest the vent hood onto the wall mount bracket, being sure that the tabs on the bracket engage the slots on t
REV 2 - 1502191555L-C2-38715INSTALLATION (cont.)VENT PIPINGA cutout will need to be made in the roof to route the piping through; and must be sealed w
REV 2 - 1502191555L-C2-38716FAN ASSEMBLY1. Locate the (4) nuts pre-installed to the ceiling of the vent hood, and using a 3/8" nut driver, loos
REV 2 - 1502191555L-C2-38717Fig. 17-3 Install fi lter spacer (if applicable)(Front of vent hood)Filter spacer installedFig. 17-4 Install fi lters(Baffl
REV 2 - 1502191555L-C2-38718ELECTRICALA 120VAC (15 AMP minimum) GFCI GROUNDED 3-wire receptacle (not included) is required within the vicinity of the
REV 2 - 1502191555L-C2-38719Fig. 19-1 Install Fire Magic Duct CoverDuct cover(Flush)(transition, vent piping, & electrical not shown for clarity)D
REV 2 - 1502191555L-C2-3872AVERTISSEMENT:Pour éviter le risque de dégats matériels et/ou de dommage corporel, le travail d'installation et le câb
REV 2 - 1502191555L-C2-38720OPÉRATIONVENTILATEUR LUMIÈRESVENTILATEUR DE CAPOT DE PASSAGEPour faire fonctionner les ventilateurs, il suffi t de tourner
REV 2 - 1502191555L-C2-38721Fig. 21-1 Control knobsFANSLIGHTSVENT HOOD FANSTo operate the fans, simply turn the fan knob located on the front right of
REV 2 - 1502191555L-C2-38722SERVICING AND CLEANINGFig. 22-2 Clean grease fi ltersFig. 22-1 Clean vent hoodWipe with grainPress in lever and removeThe u
REV 2 - 1502191555L-C2-38723SERVICING AND CLEANING (cont.)REPLACING HALOGEN BULBSImportant: ONLY REPLACE WITH 120V / 50 WATT HALOGEN BULB(S).Important
REV 2 - 1502191555L-C2-38724NOTES PAGEPlease use this page to record any information that you may want to have at hand.
REV 2 - 1502191555L-C2-38725TROUBLESHOOTINGIf you have trouble with this vent hood, please use this list to identify the problem. By trying one or mor
26Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746 Quality Check Date:_________________Electrical Leak Test: ________
REV 2 - 1502191555L-C2-3873CONTENTSGETTING STARTEDIMPORTANT PRE-INSTALLATION AND SAFETY INFORMATION ... 5SPEC
REV 2 - 1502191555L-C2-3874L'INFORMATION IMPORTANTE DE PRÉINSTALLATION ET DE SÛRETÉAVERTISSEMENT!1. Lisez toutes les instructions.2. CE CAPOT D
REV 2 - 1502191555L-C2-3875IMPORTANT PRE-INSTALLATION AND SAFETY INFORMATIONWARNING!1. Read all instructions.2. THIS VENT HOOD IS FOR OUTDOOR, WALL
REV 2 - 1502191555L-C2-3876SPECIFICATIONS AND DIMENSIONS36-VH series 42-VH series 48-VH series 60-VH seriesSpecifi cation Value Value Value ValueUnit h
REV 2 - 1502191555L-C2-3877SPECIFICATIONS AND DIMENSIONS (cont.)The following are the minimum tools required for the installation of your vent hood co
REV 2 - 1502191555L-C2-387836-VH-6 42-VH-6 48-VH-6 60-VH-6Item Description Part No. Qty. Part No. Qty. Part No. Qty. Part No. Qty.1.Transition VH-11 1